ENVIROMUX-2D
Small Enterprise Environment Monitoring System

ENVIROMUX-2D
Product Highlights
- Configure Smart Alerts for different event combinations
- 2 external configurable sensors, 5 digital inputs, 1 output relay
- User-programmable IP camera snapshots
- Linux inside
- Cascade up to 5 units via Ethernet connection (1 master, 4 slaves)
- Triggered Events can send SSH commands to soft shutdown or reboot machines
RJ45 Sensor Ports
- Two female RJ45 jacks for connecting NTI temperature, humidity, liquid detection, smoke detection, glass break, vibration, motion sensors, and more.
- Two levels of user-defined alerts – non-critical and critical.
- Provides +12 VDC, 100 mA for each port.
Dry Contact Closures
- Five screw terminal pairs for connecting dry contact devices and the liquid detection sensor.
- Potential-free.
- Output voltage: +5 V DC
- Current limited to 10 mA
- Maximum resistance to close contact: 300K Ohm
Output Relay
- One screw terminal pair.
- Potential-free relay switch contacts.
- Normally open / normally closed connection points.
- Maximum switching load: 0.5A at 125VAC, 1A at 30VDC, 0.5A at 48VDC.
USB Ports
- Two female USB Type A connectors for connecting USB modem or for downloading log data to USB flash drive.
- One female USB Type B connector for connecting a PC for serial terminal access.
Ethernet Port
- One female RJ45 connector.
- 10/100 Base-T Ethernet interface.
- Supports full- and half-duplex.
Power Output
- AUX Power
- One screw terminal pair.
- Provides +12 VDC, 500 mA.
Optional Back-Up Battery
- Rechargeable sealed lithium battery.
- Provides back-up for two hours.
MTBF
- E-2D: 229,580 hours.
- E-2DB: 230,693 hours.
Protocols
- HTTP/HTTPS, SNMP V1/V2c/V3, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSHv2, SSLv3, TLS v1.2, LDAPv3, XOAUTH2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, IPV6, WAP 2.0, RADIUS
- Support for XOAUTH2 provides higher security authentication for email accounts (e.g. Gmail).
- Compatible with any SNMP management software.
- The unit can be polled via SNMP.
- Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or USB serial interface.
- An IP address can be assigned to the E-2D automatically by a DHCP server.
- Generates SNMP traps, email alerts, syslog messages, and SMS messages (via USB 3G modem).
- Alerts are posted in event log, which is accessible through Web user interface.
- Email alerts can be sent to 17 addresses.
Dimensions
- WxDxH: 5.82x3x1.75 in (148x76x44 mm)
- Optional 1RU rackmount kit available
(E-RK1-2D).- The ENVIROMUX system can be mounted so that the sensor connectors are facing the front or back of the rack.
Weight
- E-2D: 1.0 lb (0.45 kg)
Power
- Dual DC power.
- If the first power source fails, the unit will automatically, without interruption, switch over to the second power source before switching to the optional battery backup.
- 100 to 240 VAC at 50 or 60 Hz via AC adapter.
- Includes one country-specific AC adapter. The second AC adapter is sold separately.
- Power consumption: 10W.
- Optional 24VDC power.
- Accepts 9~36VDC (24VDC nominal).
- For installation in a 24V Telecom environment.
- Use the PWR-48V-12V1-6A DC-DC power converter to install the E-2D in a 48V or 24V Telecom environment.
Environmental
- Operating temperature:
- E-2D: 32 to 140°F (0 to 60°C)
- E-2D-IND: -4 to 167°F (-20 to 75°C)
- Storage temperature: -22 to 140°F (-30 to 60°C).
- Operating /Storage Relative Humidity: 17 to 90% non-condensing RH.
Regulatory Approvals
- CE, RoHS
- EN51055, EN50121-3-2
Web Interface
- Configuration can be done over the Internet/LAN or 3G data connection via Web page.
- 3G data connection requires a USB 3G modem with a data plan.
- Email and SMS alerts can be sent through the modem instead of the Ethernet connection.
- 3G data connection requires a USB 3G modem with a data plan.
- Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Google Chrome, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC.
- Configure sensor’s thresholds, alarm methods, formats of alerts, and system data log.
- Customize SMS messages and email subject headers for sensor alerts.
- View/edit sensors’ current values, thresholds and alert statuses.
- All sensors connected, including up to 8 Remote Temperature/Humidity Sensors over IP, to the E-2D can be viewed on one summary page.
- All sensors in alert can be quickly viewed on the alert summary page to enable timely responses.
- User configurable settings allow sensors to return to normal status when alert condition clears, without manually acknowledging/dismissing the alert.
- View/edit entries stored in the system logs.
- Event log records system events such as alerts, user login/logout, failed email messages, etc.
- Data log records samples of sensor readings. User specified sampling time period.
- Both the event log and the data log store up to 1,000 entries.
- The log can be downloaded as a tab-delimited plain text file.
- Configure IP information (address, subnet mask, default gateway, DNS, etc.), user administrative settings, and data logging settings.
- Upload custom x509 certificates.
- Up to 16 users can access the web page at one time.
- Configure up to 50 sensor conditions (events)
- Configure up to 20 Smart Alerts to use different event combinations to send alert messages.
- Up to five units can be used together to increase the number of sensors connected.
- Cascade up to four E-2D/5D/16D units as slaves to one E-2D/5D/16D master unit via Ethernet connection.
- Each master and slave unit needs its own unique IP address.
- IP sensors can only be connected to a master unit.
- Uses a single Web interface for all systems/sensors connected.
- Cascade up to four E-2D/5D/16D units as slaves to one E-2D/5D/16D master unit via Ethernet connection.
- Multi-language support – English, German, Chinese, and Japanese.
Front Panel Interface
- LEDs indicate the following:
- “Fault” (red) lights up if a sensor goes out of range of a configurable threshold.
- “Power” (green) lights up when the device is powered.
- Restore Defaults button – use to manually restore the E-2D back to factory settings.
- System Reset button – use to manually reboot/restart the firmware for the E-2D.
USB Serial Interface / Telnet / SSH
- Configure, control and monitor over the text-based menu system accessible via USB console port, Telnet, and SSH.
- Access is controlled via username/password.
- System stores encrypted login information.
- Two user levels: user and administrator.
- Multi-language support – English, German, Chinese, and Japanese.
- Telnet and SSH can be enabled or disabled.
- Network Security Enhancement: Disabling Telnet can prevent unsecure text menu access to the E-2D.
Network Operation
- Automatically configures network settings received from a connected DHCP server.
- If a DHCP server is not found, the default static IP address will be used.
- SNMP support, allowing integration into network management platforms.
- Control output relays via SNMP SET commands to power on/off external devices.
- SET command can be sent from SNMP software, MIB browser (Windows), or command line (Linux).
- Control output relays via SNMP SET commands to power on/off external devices.
- Updating the system firmware.
Mobile Summary Page (view product demo)
- View summary page on mobile devices – smartphones, tablets, etc.
- Summary page lists all connected sensors’ current values and alert statuses.
Open Source Monitoring Integration
- SNMP Plugin for Nagios
- NTI SNMP Plugin for Zabbix
- Using Multi Router Traffic Grapher.
Optional Management Software
- Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 E-2D/5D/16D, E-MICRO-T(RHP), E-1W(P), E-SEMS-16(U), IPDU-S4/8 units and all connected sensors.
- Push configuration changes to multiple connected units in a group at once.
- E.g. new users, mail server, network settings, security settings, system settings, etc.
Optional Android App for Tablet/Phone
- Optional Android App provides an easy-to-use interface for monitoring and displaying sensor statuses from one E-2D/5D/16D.
Sensors & Accessories – Sold Separately
Environmental Sensors
- Remote Temperature/Humidity Sensor over IP
- Temperature Sensors
- RTD Temperature Transmitters/Sensors
- Temperature/Humidity Sensors
- Industrial Temperature/Humidity Sensors
- Rope-Style Leak Detectors
- Spot Leak Detectors
- Under Carpet & Tape-Style Detectors
- Liquid Level Float Switches
- Ultrasonic Level Transmitter
- Smoke Detectors
- Gas Detectors
- Air Flow/Velocity Detectors
- Outdoor Temperature Sensor
- Wind Speed Sensor
- Barometric Pressure Transmitter
- Pressure Sensors
Power Relays & Sensors
- Power Over Ethernet Adapters
- AC Voltage Detectors
- AC & DC Power Monitors
- Hall-Effect Sensors
- 3-Phase Power Monitors/Transducers
- Current Transformers
Security Sensors & Access Control
- Door Contact Sensors
- Vibration & Glass Break Sensors
- Motion Sensors
- Tamper Switch
- Emergency/Panic Button
- Access Control
Alert & Communication Accessories
- Automatic Voice Dialer Systems
- USB Modems
- IP Surveillance Cameras
- Siren Alarms
- Alarm Beacons
- Triggerable Audio Players
Sensor Accessories
- Digital Input/Output Expanders
- Fiber Converter/Extender
- Sensor Converters – 4-20mA, 5VDC
- Sensor Cables
- Surge Protectors
- Intrinsically Safe Barrier
Optional Replacement Back-up Battery
- Data Sheet